Concerning partial discharge detection in cable lines using high-frequency sensors
Partial discharges result in cable line faults that can occur in defective insulation systems made of rubber, polyethylene, XLPE, and flexible PVC. Insulation defects may occur due to disruptions in their production process, cable installation, and operational conditions. Therefore, the diagnostic a...
Tallennettuna:
Päätekijät: | , , , , , |
---|---|
Aineistotyyppi: | Статья |
Kieli: | English |
Julkaistu: |
2023
|
Aiheet: | |
Linkit: | https://dspace.ncfu.ru/handle/20.500.12258/24286 |
Tagit: |
Lisää tagi
Ei tageja, Lisää ensimmäinen tagi!
|
id |
ir-20.500.12258-24286 |
---|---|
record_format |
dspace |
spelling |
ir-20.500.12258-242862023-08-04T11:44:02Z Concerning partial discharge detection in cable lines using high-frequency sensors Morozova, T. F. Морозова, Т. Ф. Demin, M. S. Демин, М. С. Bondarchuk, A. Y. Бондарчук, А. Ю. High-frequency sensors Partial discharge Partial discharges result in cable line faults that can occur in defective insulation systems made of rubber, polyethylene, XLPE, and flexible PVC. Insulation defects may occur due to disruptions in their production process, cable installation, and operational conditions. Therefore, the diagnostic and monitoring of partial discharge occurrence in cable insulation help prevent emergencies in damaged cable line sections. Partial discharge registration is a non-destructive diagnostic method that helps assess the cable line condition and localize the detected defects. There are various methods of operational monitoring and partial discharge cause analysis based on operative partial discharge sensors. The assessment of cable line condition depends on the efficiency of signal detection and processing by the sensors used. This article reviews the problems of detecting and localizing partial discharges in cable lines and junction boxes using HFCT and UHF sensors. Having analyzed the capabilities of these sensors, we believe that the combined usage of HFCT and UHF sensors is the best method of detecting and localizing partial discharge within the entire cable system (lines and junction boxes). 2023-08-04T11:43:17Z 2023-08-04T11:43:17Z 2023 Статья Morozova, T., Demin, M., Bondarchuk, A. Concerning partial discharge detection in cable lines using high-frequency sensors // E3S Web of Conferences. - 2023. - 390, статья № 06030. - DOI: 10.1051/e3sconf/202339006030 http://hdl.handle.net/20.500.12258/24286 en E3S Web of Conferences application/pdf |
institution |
СКФУ |
collection |
Репозиторий |
language |
English |
topic |
High-frequency sensors Partial discharge |
spellingShingle |
High-frequency sensors Partial discharge Morozova, T. F. Морозова, Т. Ф. Demin, M. S. Демин, М. С. Bondarchuk, A. Y. Бондарчук, А. Ю. Concerning partial discharge detection in cable lines using high-frequency sensors |
description |
Partial discharges result in cable line faults that can occur in defective insulation systems made of rubber, polyethylene, XLPE, and flexible PVC. Insulation defects may occur due to disruptions in their production process, cable installation, and operational conditions. Therefore, the diagnostic and monitoring of partial discharge occurrence in cable insulation help prevent emergencies in damaged cable line sections. Partial discharge registration is a non-destructive diagnostic method that helps assess the cable line condition and localize the detected defects. There are various methods of operational monitoring and partial discharge cause analysis based on operative partial discharge sensors. The assessment of cable line condition depends on the efficiency of signal detection and processing by the sensors used. This article reviews the problems of detecting and localizing partial discharges in cable lines and junction boxes using HFCT and UHF sensors. Having analyzed the capabilities of these sensors, we believe that the combined usage of HFCT and UHF sensors is the best method of detecting and localizing partial discharge within the entire cable system (lines and junction boxes). |
format |
Статья |
author |
Morozova, T. F. Морозова, Т. Ф. Demin, M. S. Демин, М. С. Bondarchuk, A. Y. Бондарчук, А. Ю. |
author_facet |
Morozova, T. F. Морозова, Т. Ф. Demin, M. S. Демин, М. С. Bondarchuk, A. Y. Бондарчук, А. Ю. |
author_sort |
Morozova, T. F. |
title |
Concerning partial discharge detection in cable lines using high-frequency sensors |
title_short |
Concerning partial discharge detection in cable lines using high-frequency sensors |
title_full |
Concerning partial discharge detection in cable lines using high-frequency sensors |
title_fullStr |
Concerning partial discharge detection in cable lines using high-frequency sensors |
title_full_unstemmed |
Concerning partial discharge detection in cable lines using high-frequency sensors |
title_sort |
concerning partial discharge detection in cable lines using high-frequency sensors |
publishDate |
2023 |
url |
https://dspace.ncfu.ru/handle/20.500.12258/24286 |
work_keys_str_mv |
AT morozovatf concerningpartialdischargedetectionincablelinesusinghighfrequencysensors AT morozovatf concerningpartialdischargedetectionincablelinesusinghighfrequencysensors AT deminms concerningpartialdischargedetectionincablelinesusinghighfrequencysensors AT deminms concerningpartialdischargedetectionincablelinesusinghighfrequencysensors AT bondarchukay concerningpartialdischargedetectionincablelinesusinghighfrequencysensors AT bondarčukaû concerningpartialdischargedetectionincablelinesusinghighfrequencysensors |
_version_ |
1809808536097521664 |